Detail Produk
Label Produk
| Model kontaktor | LCI | D09 | DT20 | D12 | DT25 | D18 | DT32 | D25 | DT40 | D32 |
| arus operasi (le) | Dalam AC-3,θ≤60℃ | A | 9 | | 12 | | 18 | | 25 | | 32 |
| (Ue ≤ 440 V) | Dalam AC-1,θ≤60℃ | A | 25 | 20 | 25 | 25 | 32 | 32 | 40 | 40 | 50 |
| Tegangan operasi terukur (Ue) | batas atas | V | 690 | | 690 | | 690 | | 690 | | 690 |
| Rentang frekuensi | Di bawah arus operasi | Hz | 25...400 | | 25...400 | | 25...400 | | 25...400 | | 25...400 |
| Batas atas arus pemanas yang disepakati | 0“60℃ | A | 25 | 20 | 25 | 25 | 32 | 32 | 40 | 40 | 50 |
| Kapasitas koneksi terukur (440V) | Mematuhi standar IEC947 | | 250 | 250 | 300 | 450 | 550 |
| Kapasitas pemutusan terukur (440V) | Mematuhi standar IEC947 | | 250 | 250 | 300 | 450 | 550 |
| Model kontaktor | LCI | D38 | D40A | D50A | D65A | D80 | D95 | D115(1) | D150(1) | D170 |
| arus operasi (le) | Dalam AC-3,θ≤60℃ | A | 38 | 40 | 50 | 65 | 80 | 95 | 115 | 150 | 170 |
| (Ue ≤ 440 V) | Dalam AC-1,θ≤60℃ | A | 50 | 60 | 80 | 80 | 125 | 125 | 200 | 200 | 200 |
| Tegangan operasi terukur (Ue) | batas atas | V | 690 | 690 | 690 | 690 | 690 | 690 | 1000 | 1000 | 1000 |
| Rentang frekuensi | Di bawah arus operasi | Hz | 25...400 | 25...400 | 25...400 | 25...400 | 25...400 | 25...400 | 25...400 | 25...400 | 25...400 |
| Batas atas arus pemanas yang disepakati | 0“60℃ | A | 50 | 60 | 80 | 80 | 125 | 125 | 200 | 200 | 200 |
| Kapasitas koneksi terukur (440V) | Mematuhi standar IEC947 | | 550 | 800 | 900 | 1000 | tahun 1100 | tahun 1100 | tahun 1260 | tahun 1660 | tahun 1660 |
| Kapasitas pemutusan terukur (440V) | Mematuhi standar IEC947 | | 550 | 800 | 900 | 1000 | tahun 1100 | tahun 1100 | tahun 1100 | tahun 1400 | tahun 1400 |