94102811

Thyssen Escalator and Moving Walk Fault Codes: E1–E8 and AA Explained

Thyssen escalators and moving walks are equipped with monitoring systems designed to detect abnormal operating conditions. When a fault occurs, the control system displays a corresponding error code to help maintenance technicians identify the affected system or component.

Understanding these fault codes is an important first step in escalator and moving walk troubleshooting.

This guide explains the meanings of the Thyssen escalator and moving walk fault codes E1 through E8, as well as the combined fault indication AA.

Thyssen-Escalator-Fault-Codes-1200x800

1. Thyssen Escalator and Moving Walk Fault Code List

The following table summarizes the fault codes and their corresponding descriptions.

Fault Code

Fault Description

E1 Reserved Fault Interface
E2 Handrail
E3 Chain Tension
E4 Step
E5 Comb Plate
E6 Motor Phase Loss
E7 Motor Overheating
E8 Drive Chain
AA Two or More Faults Detected

2. Detailed Explanation of Thyssen Escalator Fault Codes

E1 – Reserved Fault Interface

E1 indicates a reserved fault interface in the control system.

The original fault code reference identifies E1 as a reserved interface but does not provide additional information about its triggering conditions or troubleshooting procedures.

E2 – Handrail Fault

E2 corresponds to the escalator handrail system.

The handrail is an important part of escalator operation, providing passengers with continuous support while the steps are moving.

When E2 is displayed, the fault indication is associated with the handrail system.

E3 – Chain Tension Fault

E3 indicates a chain tension-related fault.

The escalator chain system is essential for transmitting mechanical movement. Chain tension is an important factor in maintaining stable operation.

E3 identifies an abnormal condition associated with chain tension monitoring.

E4 – Step Fault

E4 corresponds to the escalator step system.

Escalator steps are continuously monitored as part of the equipment’s operating and safety systems. An E4 indication identifies a fault associated with the steps.

E5 – Comb Plate Fault

E5 indicates a fault associated with the escalator comb plate.

The comb plate is installed at the entrance and exit of the escalator, where its teeth engage with the step grooves. It is an important component of the escalator’s passenger safety system.

E6 – Motor Phase Loss

E6 indicates motor phase loss.

The motor power supply is essential for normal escalator operation. A phase-loss indication identifies an abnormal condition associated with the motor’s electrical supply.

E7 – Motor Overheating

E7 indicates motor overheating.

The escalator drive motor provides the power required to operate the equipment. Motor temperature is an important operating parameter, and an overheating indication should be investigated before normal operation resumes.

E8 – Drive Chain Fault

E8 corresponds to the escalator drive chain.

The drive chain transmits power through the mechanical drive system. This fault code identifies an abnormal condition associated with the drive chain.

AA – Multiple Faults

AA indicates that two or more faults are present.

Unlike individual fault codes, AA represents a combined fault condition rather than one specific component.

When AA appears, the individual fault information should be identified before determining the appropriate inspection procedure.

Conclusion

Understanding Thyssen escalator and moving walk fault codes helps maintenance technicians identify which system is associated with an abnormal operating condition.

From handrail and chain tension monitoring to step, comb plate, motor, and drive chain faults, each code provides an important reference for further inspection.

For accurate diagnosis, always refer to the applicable Thyssen controller documentation, equipment specifications, and maintenance procedures.


Post time: Nov-24-2026