| CHARACTERISTIC | SYMBOL | RATING | UNIT |
| Control Input Voltage (DC) (Note 1) | VF (IN) | 6 | V |
| Control Input Current(DC) | IF (IN) | 20 | mA |
| OUTPUT (LOAD) | |||
| Repetitive Peak Off-State Voltage TSS10J45S |
VDRM | 600 | V |
| Nominal AC Line Voltage TSS10J45S |
VAC | 240 | V |
| R.M.S On-State Current | IT(RMS) | 10 | A |
| Peak One Cycle Surge On-State Current (Non-Repetitive) | ITSM | 100(50Hz) | A |
| Operating Frequency Range | f | 45~65 | Hz |
| Isolation Voltage (t=1min., Input to Output and Input/Output to Base) | BVg/AC | 1500 | V |
| Operating Temperature Range | Topr | -30~80 | ℃ |
| Storage Temperature Range | Tstg | -30~80 | ℃ |
Note 1: Driving input rating : Insert an external resistance into SSR when the power supply over 6V is used.
Note 2: Don't dip the SSR body into the organic solvent like Trichloroethylene, when washing the flux on the terminal.
Note 3: For installation of SSR, use spring wahers, etc., to prevent screws from loosening.